SiPM for Time Domain NIR Spectroscopy

SiPM for Time Domain NIR Spectroscopy - Hallo friendsCAR ON REPIYU, In the article you read this time with the title SiPM for Time Domain NIR Spectroscopy, We have prepared this article for you to read and retrieve information therein. Hopefully the contents of postings Article car review, Article mobile review, We write this you can understand. Alright, good read.

Title : SiPM for Time Domain NIR Spectroscopy
link : SiPM for Time Domain NIR Spectroscopy

Read too


SiPM for Time Domain NIR Spectroscopy

 IEEE JSSC publishes an open-access paper "Large-Area, Fast-Gated Digital SiPM With Integrated TDC for Portable and Wearable Time-Domain NIRS" by Enrico Conca, Vincenzo Sesta, Mauro Buttafava, Federica Villa, Laura Di Sieno, Alberto Dalla Mora, Davide Contini, Paola Taroni, Alessandro Torricelli, Antonio Pifferi, Franco Zappa , and Alberto Tosi from Politecnico di Milano.

"We present the design and characterization of a large-area, fast-gated, all-digital single-photon detector with programmable active area, internal gate generator, and time-to-digital converter (TDC) with a built-in histogram builder circuit, suitable for performing high-sensitivity time-domain near-infrared spectroscopy (TD-NIRS) measurements when coupled with pulsed laser sources. We used a novel low-power differential sensing technique that optimizes area occupation. The photodetector is a time-gated digital silicon photomultiplier (dSiPM) with an 8.6-mm 2 photosensitive area, 37% fill-factor, and ~300 ps (20%–80%) gate rising edge, based on low-noise single-photon avalanche diodes (SPADs) and fabricated in 0.35- μm CMOS technology. The built-in TDC with a histogram builder has a least-significant-bit (LSB) of 78 ps and 128 time-bins, and the integrated circuit can be interfaced directly with a low-cost microcontroller with a serial interface for programming and readout. Experimental characterization demonstrated a temporal response as good as 300-ps full-width at half-maximum (FWHM) and a dynamic range >100 dB (thanks to the programmable active area size). This microelectronic detector paves the way for a miniaturized, stand-alone, multi-wavelength TD-NIRS system with an unprecedented level of integration and responsivity, suitable for portable and wearable systems."



Thus Article SiPM for Time Domain NIR Spectroscopy

That's an article SiPM for Time Domain NIR Spectroscopy This time, hopefully can give benefits to all of you. well, see you in posting other articles.

You are now reading the article SiPM for Time Domain NIR Spectroscopy with the link address https://caronrepiyu.blogspot.com/2020/11/sipm-for-time-domain-nir-spectroscopy.html

Subscribe to receive free email updates:

0 Response to "SiPM for Time Domain NIR Spectroscopy"

Post a Comment